south-seattle-rectangle

Seattle South Datacenter

Our NOC and state-of-the-art, 42,000-square-feet colocation facility is situated on Seattle’s Intergate West Campus – part of the largest Internet campus in North America. The solid-floor, steel and concrete construction was purpose-built with datacenter use in mind. Every aspect was taken into consideration, from our 14’ ceilings down to the electrically conductive, grounded floor tiles were designed and reinforced to support live loads. The facility boasts a “Seismic Zone 3 Critical” rating – the highest rating necessary for Western Washington earthquake resistance.


View Larger Map

● 45,600 sq. ft.
● 6MW Capacity
● VESDA Smoke Detection
● ECARO Fire Suppression
● 24x7x365 Staff
● Private Colocation Suites and Cages

googleplus

Datacenter Specs

  • Purpose-built, high-density datacenter
  • Private colocation suites and cages
  • Seismic Zone 3 construction
  • 45,600-square-foot facility (4 stories)
  • Outside the 500-year flood plain
  • SSAE16 certification, PCI and HIPAA ready
  • 24×7 on-site technical staff, industry-trained and background-checked
  • Remote hands services for reboots and power cycles
  • Multiple methods of contact: phone, email, online, face-to-face, customer portal
  • Workspace, wi-fi, available day or night
  • Full-sized loading dock with easy datacenter access
  • Private office suits available
  • Secure underground parking
  • 18” raised floor with underfloor leak and smoke detection
  • Roof rights and many antennas in place
  • 6MW capacity
  • AC and DC protected power
  • 4 x diesel generators load tested and certified quarterly 4.5MW total
  • Permanently installed load banks
  • Emergency fuel contracts with multiple providers in place
  • 7,000 gallons diesel on-site – fuel polishing systems regularly tested and documented for quality
  • 2 Seattle City Light power vaults
  • True “A” and “B” UPS redundancy N+1
  • Supports 250 watts per foot
  • High-density cabinets to 15kW
  • 2N AC UPS design available 110Volt AC, 208Volt AC and 208Volt – 3 phase UPS circuits available
  • Cooling redundancy: 2N
  • Seattle is powered by the low-cost, abundant and clean hydropower of Seattle City Light – 95% clean energy.
  • Cost savings of inexpensive power is enhanced by energy efficient design and state-of-the-art mechanical systems – we achieve deep savings through economizer and evaporative free cooling 90% of year
  • Carrier-neutral facility
  • Over 20 providers on-site
  • Redundant, fully meshed routers and switching
  • Multiple 10 GigE connections to the Internet
  • Private 10G dark fiber to the Westin and Downtown Seattle Datacenter
  • Diverse fiber entry points and fiber risers
  • Direct connection with the Seattle Internet Exchange (SIX)
  • Low-latency paths to Asia and East Coast
  • 24×7 on-site security staff
  • 24×7 key card access
  • 24×7 camera surveillance and 90-day video retention (48 cameras)
  • Closed-circuit monitoring with CCTV in two NOCs
  • Entry and exit logs
  • VESDA smoke detection
  • ECARO-25 gas fire suppression
  • Pre-action dry pipe fire suppression systems throughout datacenter
  • Biometrics available to suites/cages

Download the Datacenter Specs

View Our Downtown Seattle Facility